72% Heavy Rare Earth ratio and a Second Zircon Hf Product
Released
Released
Announcement PDF
ASX: VTM Victory Metals Limited ACN 124 279 750
Suite 1, 295 Rokeby Road, Subiaco Western Australia 6008
Email: admin@victorymetalsaustralia.com www.victorymetalsaustralia.com Page 1 of 7
ASX ANNOUNCEMENT 28 April 2026
North Stanmore delivers globally exceptional 72% Heavy
Rare Earth ratio and a second zircon Hafnium product
Victory Metals Limited (ASX:VTM) (“Victory” or the “Company”) is pleased to
announce a landmark separation achievement at its 100% owned North Stanmore
Heavy Rare Earth (HREO) Project in Western Australia.
Metallurgical and mineralogical test work has confirmed recovery of relict primary
zircon crystals from coarse-grained ore by Heavy Liquid Separation (HLS), a low-
cost separation process. The zircon contains significant concentrations of
Dysprosium, Terbium, Yttrium, Scandium & Hafnium. These zircon-rich high
specific gravity ~3.5 (SG) fractions have concentrations of ~10,000 ppm Total Rare
Earth Oxide (TREO) and Heavy Rare Earth Oxide (HREO) / Total Rare Earth Oxide
(TREO) ratios of up to 72% and Scandium concentrations ranging up to 398 ppm.
These results reclassify the coarse-grained HLS stream from being a processing
liability into a standalone revenue stream which is expected to further enhance
project economics.
HIGHLIGHTS
♦ 72% HREO:TREO ratio achieved in a clean pre-concentrate among the
highest heavy rare earth ratios reported globally from a clay hosted system
♦ 42x upgrade in the heavy zircon fraction from 741 ppm Zr headgrade to
3.14% Zr and 697ppm Hf
♦ 21.5x Heavy Rare Earth (HREE) upgrade from 286 ppm to 6,161 ppm HREE
in just 1.9% of the mass, captured by simple, low-cost Heavy Liquid
Separation (HLS)
♦ Two products, one process the same HLS step delivers a separate zircon
concentrate at +3.5 SG carrying Dy, Tb, Y, Sc and Hf credits
Up to 390 ppm Scandium (Sc₂O₃) in the HREE pre-concentrate a 16x
upgrade enriched in HREE Dy, Tb & Y
♦ Negligible incremental cost with no additional mining, drilling or feedstock
♦ Pending Pre-Feasibility Study (PFS) not reliant on this new revenue
stream
Page 2 of 7
Victory Metals Chief Executive Officer and Executive Director Brendan Clark
commented: “North Stanmore has just delivered a 72% heavy rare earth ratio a
number that puts us in the top tier of HREE projects globally, and it has come from
a fraction the industry would normally discard.
The same simple gravity step gives us a second high grade zircon concentrate
product carrying Hafnium and Scandium. Two revenue streams, one process, and
effectively zero additional cost. That is the kind of metallurgical result that
fundamentally re-rates a project.
Our pending PFS does not need this stream to succeed. Everything announced
today is upside. With Dysprosium, Terbium, Yttrium, Scandium & Hafnium and our
process IP entirely non-Chinese, Victory positioning Victory as a future fast tracked
producer of heavy rare earths and strategic defence metals from a non Chinese
supply chain
Heavy Liquid Separation (HLS)
HLS is a low-cost, well-established gravity technique that separates minerals by
density. The objective of this program was to test whether the coarse +500 µm
screen oversize which was previously regarded as a processing liability could be
upgraded into a saleable concentrate by density alone, without flotation, leaching
or additional reagents.
HLS test work was completed on the same composite sample previously used in
the Company's deslime, Multi Gravity Separator (MGS) and flotation studies,
allowing direct comparison across separation techniques.
Three size fractions from the +500 µm screen oversize were tested individually:
• Coarse fraction: −1,000 +300 µm
• Medium fraction: −300 +106 µm
• Fine fraction: −106 +53 µm
Each size fraction was separated into four specific gravity (SG) bands:
• −2.5 (light gangue: quartz, feldspar)
• +2.5 to −3.0 (intermediate gangue)
• +3.0 to −3.5 (target HREE-bearing phase)
• +3.5 (heavy minerals, including zircon)
Results are reported as elemental grade (TREE, LREE, HREE in ppm), mass
distribution, and elemental distribution across each SG fraction.
Coarse fraction (−1,000 +300 µm) headline delivers the most pronounced
HREE/LREE separation across the SG bands, consistent with improved mineral
liberation at coarser grain sizes. 47% of all HREE report to the combined +3.0 SG
fractions, despite these representing only 2.5% of the mass.
Page 3 of 7
The −3.5+3.0 SG band is the key HREE pre-concentrate, upgrading HREE grade
from a 184 ppm calculated head to 6,161 ppm — a 33x upgrade — at a 72%
HREO:TREO ratio, in just 1.9% of the mass.
The full coarse-fraction results are presented below, with the pre-concentrate band
highlighted.
SG
fraction
Mass
%
TREE
(ppm)
LREE
(ppm)
HREE
(ppm)
HREO:TREO
TREE
dist
LREE
dist
HREE
dist
−2.5 12.0% 128 88 39 0.34 18% 21% 15%
+2.5 −3.0 85.6% 314 156 66 0.33 48% 55% 38%
+3.0 −3.5 1.9% 8,523 2,362 6,161 0.72 23% 11% 41%
+3.5 0.6% 1,622 1,123 239 0.24 11% 14% 6%
Calc.
head
100% 449 335 184 0.42 100% 100% 100%
Table 1: HLS results, Sample 1, −1,000 +300 µm size fraction. ★ Key HREE pre-concentrate.
LREE = La, Ce, Pr, Nd, Sm. HREE = Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Y.
Figure 1: Typical Schematic of Heavy Liquid Separation (HLS) conducted on North Stanmore feed sample.
Not to scale.
Page 4 of 7
Figure 2: Rare Earth Oxide basket composition of the +300 -1mm SG -3.5+3.0 stream generated using HLS
Pre-concentrate selectivity confirmed
The −3.5+3.0 SG fraction captures 41% of all HREE in just 1.9% of the mass in the
coarse fraction. This selectivity for HREE in the 3.0–3.5 SG band is the critical finding
of this test work and the basis for a high-grade HREE pre-concentrate stream.
Medium and fine size fractions.
Both the medium (−300 +106 µm) and fine (−106 +53 µm) fractions confirm the
same separation behaviour observed in the coarse fraction, with the −3.5+3.0 SG
band consistently delivering the highest HREO:TREO ratio. HREE/LREE separation
is somewhat less pronounced at finer sizes, consistent with reduced mineral
liberation as particle size decreases which is a positive finding, as it confirms the
coarse fraction is the natural target for the HREE pre-concentrate stream.
Page 5 of 7
Importantly, the +3.5 SG band becomes increasingly significant at finer sizes, where
it begins to capture a recoverable zircon-hafnium product (full Zr and Hf assays
detailed in the previous section).
SG fraction Mass % TREE (ppm) LREE (ppm) HREE (ppm) HREO:TREO HREE dist
−2.5 14.8% 1,241 854 388 0.31 17%
+2.5 −3.0 82.4% 630 432 197 0.31 47%
+3.0 −3.5 ★ 1.1% 8,792 2,697 6,095 0.69 20%
+3.5 1.7% 8,872 5,523 3,349 0.38 16%
Calc. head 100% 952 607 346 0.36 100%
Table 2: HLS results, Sample 1, −300 +106 µm size fraction. Key HREE pre-concentrate.
Maximum U and Th contents in the >3.5 gm/cc fraction are 57 ppm and 73.5 ppm
respectively. These yield U238 & U234 and Th232 activities of 1.45 Bq/g and 0.3 Bq/g
respectively, which indicate that the concentrates can be shipped as bulk cargo,
and will not require special containment.
Next Step - Metallurgical Test Program
A focused metallurgical program is proposed to develop and validate a separation
route capable of cleanly partitioning the −3.0+2.5 SG fraction from the heavier +3.5
SG concentrate fraction.
The objective is to confirm that the value bearing minerals report predominantly
to the high-density product while the −3.0+2.5 SG middlings and lighter gangue
can be rejected (or directed to a separate processing stream) without
unacceptable losses.
The program is expected to define recovery grade tradeoffs at each cut. HLS results
will then be used to design and benchmark a continuous dense medium
separation (DMS) circuit likely incorporating a primary DMS stage at a nominal cut
point near 3.0–3.2 SG, followed by a secondary cleaner stage at approximately 3.5
SG to upgrade the heavies. Depending on the size distribution of the feed, this may
involve a combination of dense medium cyclones for the finer fractions and dense-
medium drums or baths for the coarser material.
Supporting work is expected to cover representative sample preparation and head
assays, sizing analysis and size by size density profiling, mineralogical
characterisation (QEMSCAN or equivalent automated mineralogy) on the float,
sink and middlings products to confirm where the value minerals are deporting,
and viscosity / medium-stability testwork to assess the practicality of operating at
the higher cut densities.
Deliverables from the program will include defined optimum cut points, projected
recoveries and product grades for each density stream, a recommended flowsheet
Page 6 of 7
for downstream design, and an indicative mass and metallurgical balance suitable
for input into the next phase of engineering and economic evaluation
This announcement has been authorised by the Board of Victory Metals Limited.
For further information please contact:
Brendan Clark Jim Carden
CEO and Executive Director Investor and Media Relations
admin@victorymetalsaustralia.com jimc@bastionagency.com
Victory Metals Limited
Victory is dedicated to the exploration and development of its flagship North Stanmore
Heavy Rare Earth Elements (HREE), Scandium, Hafnium and Gallium Project located
in the Cue Region of Western Australia. The Company is committed to advancing this
world-class project to unlock its significant potential.
In August 2025, Victory Metals announced a robust Mineral Resource Estimate (MRE)
for North Stanmore, totalling 320.6 million tonnes, with most of the resource classified
in the indicated category. This positions the North Stanmore Project as Australia's
largest indicated clay heavy rare earth resource, underscoring its pivotal role as a
supplier of critical materials for the future.
North Stanmore Mineral Resource Estimate
North Stanmore August 2025 MRE (≥330ppm TREO + Sc2O3 cut-off grade)
CLASSIFICATION
MRE
TONNES
(t)
TREOSc
(ppm)
TREO
(ppm)
HREO
(ppm)
LREO
(ppm)
HREO/TREO
(%)
Sc2O3
(ppm)
Ga2O3
(ppm)
INDICATED 176,522,000 532 505 190 316 39 26 26
INFERRED 144,118,000 484 463 166 297 37 21 25
Forward-looking statements
This announcement contains “forward-looking statements”. All statements other than
those of historical facts included in this announcement are forward looking statements.
Where a company expresses or implies an expectation or belief as to future events or
results, such expectation or belief is expressed in good faith and believed to have a
reasonable basis. However, forward-looking statements are subject to risks,
uncertainties and other factors, which could cause actual results to differ materially from
future results expressed, projected or implied by such forward-looking statements. Such
risks include, but are not limited to, metals price volatility, currency fluctuations,
increased production costs and variances in ore grade or recovery rates from those
Page 7 of 7
assumed in mining plans, as well as political and operational risks and governmental
regulation and judicial outcomes. The company undertakes any obligation to release
publicly any revisions to any “forward-looking” statement.
Competent Person Statement - Professor Ken Collerson
Statements contained in this report relating to exploration results, metallurgy results,
scientific evaluation, and potential, are based on information compiled and evaluated
by Emeritus Professor Ken Collerson. Professor Collerson (PhD) Principal of KDC Geo
Consulting and Director of Victory Metals Limited, and a Fellow of the Australasian
Institute of Mining and Metallurgy (AusIMM No. 100125), is a geochemist/geologist with
sufficient relevant experience in relation to rare earth element and critical metal
mineralisation being reported on, to qualify as a Competent Person as defined in the
Australian Code for Reporting of Identified Mineral resources and Ore reserves (JORC
Code 2012). Professor Collerson consents to the use of this information in this report in
the form and context in which it appears.
Page 1 of 18
APPENDIX 1: 2012 JORC CODE
Table 1: JORC Code
Section 1: Sampling Techniques and Data
Criteria
JORC Code
explanation
Commentary
Sampling
techniques
• Nature and quality of
sampling (e.g. cut
channels, random
chips, or specific
specialised industry
standard
measurement tools
appropriate to the
minerals under
investigation, such
as downhole gamma
sondes, or handheld
XRF instruments,
etc.). These
examples should not
be taken as limiting
the broad meaning
of sampling.
• Include reference to
measures taken to
ensure sample
representivity and
the appropriate
calibration of any
measurement tools
or systems used.
• Aspects of the
determination of
mineralisation that
are Material to the
Public Report. In
cases where
‘industry standard’
work has been done
this would be
relatively simple
(e.g. ‘reverse
circulation drilling
was used to obtain
1 m samples from
which 3 kg was
pulverised to
produce a 30 g
charge for fire
assay’). In other
cases, more
explanation may be
required, such as
where there is
coarse gold that has
inherent sampling
problems. Unusual
commodities or
mineralisation types
(e.g. submarine
• Note that at the time of compiling Table 1 and reporting of significant results
that 5 drillholes in the north of the project were still pending assay return,
drillholes 2025IFAC059 to 63.
• (AC) Air core drillholes were drilled vertically and spaced 100m apart along
200m - 400m spaced drill lines.
• (AC) drilling samples were collected as 1-m samples from the rig cyclone. Each
sample was placed into large green drill bags (900mmx600mm) for temporary
storage onsite.
• Each sample was then split using a 3-tier (87.5% - 12.5%) splitter and the split
sample was placed into calico sample bags for transport to Perth.
• Sample weights and recoveries were recorded on site and weighed 1.5 - 2.5
kg depending on the sample recovery from the drill hole. The mean bulk
sample weight was 8.45kg.
• A commercial transport company was used to transport the bags to the
Victory warehouse in Perth.
• A handheld pXRF analyzer (Olympus Vanta) was used to determine
anomalous REO (Rare earth element) geochemistry (La, Ce, Pr, Nd and Y) from
the 1-m sample piles. pXRF reading times were 45 secs over 3 cycles for
multielement and REO assays. These results are not considered dependable
without calibration using chemical analysis from an accredited laboratory.
However, their integrity was checked using Certified REO -bearing
geochemical standards.
• The handheld pXRF is used as a guide to the relative presence or absence of
certain elements, including REOs vectors (La, Ce, Pr, Nd and Y) to help direct
the sampling program. Anomalous 1m samples were then transported to the
assay lab for analysis by Victory personnel. REO anomalism thresholds are
determined by VTM technical lead based on historical data analysis. Currently
the anomaly threshold is plus 30ppm Yttrium.
• Victory attended North Stanmore to collect the green sample bag which was
transported by Victory to Victory’s secure warehouse in Perth.
• Measures taken to ensure sample representivity included regular cleaning of
the rig between drill holes using compressed air and weighing the bulk
sample to ensure reasonable sample return against an expected target
weight.
• RC drill samples were collected as 1-m samples from the rig cyclone and
placed on top of black plastic, which was laid on the natural ground surface to
prevent contamination, in separate piles and in orderly rows. A hand-held
trowel was used to collect 4-m composite samples from the 1-m piles.
Compositing did not account for lithology changes. These composite samples
weighed between 2 and 3 kg.
Page 2 of 18
Criteria
JORC Code
explanation
Commentary
nodules) may
warrant disclosure of
detailed information
Drilling
techniques
• Drill type (e.g. core,
reverse circulation,
open-hole hammer,
rotary air blast,
auger, Bangka,
sonic, etc.) and
details (e.g. core
diameter, triple or
standard tube,
depth of diamond
tails, face-sampling
bit or other type,
whether core is
oriented and if so,
by what method,
etc.).
• (AC) drilling uses a three bladed steel or tungsten drill bit to penetrate the
weathered layer of loose soil and rock fragments. The drill rods are hollow
and have an inner tube with an outer barrel (similar to RC drilling).
• (AC) drilling uses small compressors (750 cfm/250 psi) to drill holes into the
weathered layer of loose soil and fragments of rock.
• (RC) Drilling used a 5½” face sampling hammer with 1,350cfm/500 psi
onboard compressor, which was occasionally supplemented with an
additional booster (2,100cfm/1,000 psi).
• After drilling is complete, an injection of compressed air is unleashed into the
space between the inner tube and the drill rods inside wall, which flushes the
cuttings up and out of the drill hole through the rod’s inner tube, resulting in
less chance of cross-contamination.
• (AC) Drilling was conducted by Bostech Drilling for the 63 drillhole
programme.
• The drill rigs were inspected daily by VTM personnel for safety and rig hygiene
Drill sample
recovery
• Method of recording
and assessing core
and chip sample
recoveries and
results assessed.
• Measures taken to
maximise sample
recovery and ensure
representative
nature of the
samples.
• Whether a
relationship exists
between sample
recovery and grade
and whether sample
bias may have
occurred due to
preferential
loss/gain of
fine/coarse material.
• The majority of samples were dry, where excessive water flows were
encountered during drilling the sample recovery was variable. The depth that
water was encountered was recorded in the database.
• Representative percussion drillhole samples were collected as 1-metre
intervals, with corresponding chips placed into chip trays and kept for
reference at VTM’s facilities.
• Measures taken to ensure sample representivity and recovery included
regular cleaning of the rig between drill holes using compressed air and
weighing the bulk sample to ensure reasonable sample return against an
expected target weight.
Logging
• Whether core and
chip samples have
been geologically
and geotechnically
logged to a level of
detail to support
appropriate Mineral
Resource estimation,
mining studies and
metallurgical
studies.
• All percussion samples in the chip trays were lithologically logged using
standard industry logging software on a notebook computer.
• All (AC) samples have been logged for lithology, alteration, quartz veins,
colour, fabrics.
• All (AC) samples have been analysed by a handheld pXRF.
• All samples were subjected to a NIR spectrometer for the identification of
minerals and the variations in mineral chemistry to detect alteration
assemblages and regolith profiles.
• All geological information noted above has been reviewed by a competent
person as recognised by JORC.
• Whether logging is
qualitative or
quantitative in
nature. Core (or
costean, channel,
etc.) photography.
• Logging is qualitative in nature.
• (AC) samples have been photographed.
• The total length and
percentage of the
relevant
intersections
logged.
• 90% of the sample intervals were logged.
Page 3 of 18
Criteria
JORC Code
explanation
Commentary
Subsamplin
g techniques
and sample
preparation
• If core, whether cut
or sawn and whether
quarter, half or all
core taken.
• Diamond drilling was PQ core.
• Half core samples were taken, with the exception of when twin samples were
collected and then the samples were quarter core.
• If non-core, whether
riffled, tube
sampled, rotary split,
etc. and whether
sampled wet or dry.
• Air core and RC sampling was undertaken on 1m intervals using a Meztke
Static Cone splitter.
• Samples from the cyclone were placed into green drill bags and were laid out
in orderly rows on the ground.
• Using a hand-held trowel, 1m samples were collected from the one-metre
drill bags after splitting of the sample.
• These samples were placed into calico bags and weighed between 1.5 and 2.5
kgs.
• For all sample types,
the nature, quality
and appropriateness
of the sample
preparation
technique.
• Samples were assayed by ALS Laboratories in Perth, a NATA Accredited
Testing Laboratory. The assay methods used include:
o ME-4ACD81: Four acid digestion followed by ICP-AES
measurement
o ME-MS81: Lithium borate fusion followed by acid dissolution and
ICPMS measurement
o ME-ICP06: Fusion decomposition followed by ICP-OES
measurement
• REOs were all analysed by ME-MS81 (four acid digestion followed by ICPMS
measurement) with results returned in their elemental form. Elements were
then converted to oxides using the appropriate stoichiometric conversion
factors.
• Base metals are assayed by ME-ICP06: Fusion decomposition.
• Non-ferrous metals are assayed by ME-4ACD81: Four acid digestion.
• Quality control
procedures adopted
for all subsampling
stages to maximise
representivity of
samples.
• Using a riffle splitter, 1m composite samples were collected from the
individual sample bags.
• Quality control of the assaying comprised the collection of a bulk repeat
sample every hole, along with the regular insertion of industry (OREAS)
standards (certified reference material) every 20 samples and blanks (beach
sand) every 50 samples. The repeat sample was collected by passing the bulk
reject obtained from the first split stage through the riffle splitter once more.
The repeat sample is not a duplicate.
• Measures taken to
ensure that the
sampling is
representative of the
in-situ material
collected, including
for instance results
for field
duplicate/second-
half sampling.
• Fourteen twin samples of quarter core (diamond PQ) were compared to the
original sample for each REO element and results were found to be
acceptable to the CP.
• Whether sample
sizes are appropriate
to the grain size of
the material being
sampled.
• Composite samples weighed between 1 and 2 Kg’s.
• Sample sizes are considered appropriate to the grain size of the material
being sampled.
Quality of
assay data
and
laboratory
tests
• The nature, quality
and appropriateness
of the assaying and
laboratory
procedures used
and whether the
technique is
considered partial or
total.
• All samples were analysed in the field using a handheld Olympus Vanta XRF
unit to identify geochemical thresholds. These results are not considered
dependable without calibration using chemical analysis. They were used as a
guide to the relative presence or absence of certain elements, including REOs
to help guide the drill program and selection of samples to be submitted for
analytical analysis.
• All pXRF anomalous samples were sent to ALS Wangara in Perth for analysis.
Over time the mineralised sample criteria has evolved from an initial sampling
threshold value of La+Ce+Nd+Pr+Y > 200ppm (for the RSC MRE), to
Ce>30ppm (for the post RSC to July 2024 MRE), and most recently Y>30ppm
(POST July 2024 to July 2025 MRE).
• Samples were submitted for sample preparation and geochemical analysis by
ALS in Wangara, Perth, a NATA accredited laboratory. All samples were
Page 4 of 18
Criteria
JORC Code
explanation
Commentary
crushed and pulverized to generate a pulp aliquot sample with 95% of the
aliquot sample passing 75µ (ALS methods CRU-31, PUL-31). Aliquots were
analysed using the following methods:
o Lithium borate fusion prior to acid dissolution and ICPMS (ALS
method ME-MS81, a total assay technique) for Ba, Ce, Cr, Cs, Dy,
Er, Eu, Ga, Gd, Hf, Ho, La, Lu, Nb, Nd, Pr, Rb, Sc, Sm, Sn, Sr, Ta, Tb,
Th, Ti, Tm, U, V, W, Y, Yb, and Zr.
o Lithium borate fusion prior to acid dissolution and ICPOES (ALS
method ME-ICP06, a total assay technique) for Al2O3, BaO, CaO,
Cr2O3, Fe2O3, K2O, MgO, MnO, Na2O, P2O5, SiO2, SrO, TiO2, and
Total.
o 4-acid digest and read by ICP-AES (ALS method ME-4ACD81, a
partial assay technique) for Ag, As, Cd, Co, Cu, Li, Mo, Ni, Pb, Sc, Tl,
and Zn (base metals).
o Thermogravimetric analysis to determine loss on ignition (LOI)
content.
• The sample preparation and analysis are considered appropriate for the
analytes.
• As a result of the pXRF analysis leading the selection criteria for assaying by a
laboratory, only 16,620 metres of drilling of the total 45,340 drill metres (or
37% of total metres) has been assayed.
• For geophysical
tools, spectrometers,
handheld XRF
instruments, etc., the
parameters used in
determining the
analysis including
instrument make
and model, reading
times, calibrations
factors applied and
their derivation, etc.
• At Victory’s Perth facility spot checks were completed on selected samples
using a handheld Olympus Vanta XRF unit. The pXRF device was used to
determine anomalous REO geochemistry (La, Ce, Nd, Pr and Y) from the 1-m
sample piles.
• pXRF reading times were 45 secs over 3 beams for multielement and REO
assays. These results are not considered dependable without calibration using
chemical analysis from an accredited laboratory. However, their analytical
accuracy was checked using REO -bearing geochemical standards.
• The pXRF results were not used for estimation.
• Nature of quality
control procedures
adopted (e.g.
standards, blanks,
duplicates, external
laboratory checks)
and whether
acceptable levels of
accuracy (i.e. lack of
bias) and precision
have been
established.
• Sample weights were measured for 174 of the AC drillholes, and recovery was
measured for 7 of the diamond drillholes. Sample recovery for the diamond
drillholes recovery was 100 %. Based on the information available, sample
recovery is acceptable for the diamond holes.
• Assay analytical precision was established by laboratory repeats and was
deemed acceptable to the Competent Person.
• OREAS 464 is a high grade ore, rare earth element (TREO = 5.10%) matrix-
matched certified reference material (MMCRM) prepared and certified by Ore
Research & Exploration. OREAS 461 is an ore grade, rare earth element (TREO
= 1.06%) matrix-matched certified reference material (MMCRM) prepared
and certified by Ore Research & Exploration. The materials constituting
OREAS 464 were sourced from Lynas Corporation’s Mount Weld Project (the
‘Central Lanthanide Deposit’) which is located 35 kilometres south of
Laverton in Western Australia. The Mount Weld source materials (waste, low
and medium grade REE ores) were found to be highly hygroscopic to the
extent that significant analytical errors would likely result during analysis
unless strict moisture handling procedures were adhered. To avoid this
complication, the hygroscopic property was destroyed by roasting the
materials at 900°C for 2 hours.
o The overall performance of standards was deemed to be
acceptable. It was noted that Y in the CRM OREAS461 have
expected values above the detection limits of the lab method
ME_MS81. Dy and Tb were within action limits.
o OREAS464 which is a higher grade standard returned good results
within limits for Y, Dy, and Tb.
• The overall performance of the blanks was deemed to be acceptable to the
CP. There was a small increase in Yttrium values observed and no increase in
values such as terbium and dysprosium.
• Field diamond duplicate data points taken from the same drillholes is
available only for 14 samples from diamond drill core. The mean grade of the
Page 5 of 18
Criteria
JORC Code
explanation
Commentary
original sample was generally reproduced by the duplicate for the various
analytes and is acceptable to the Competent Person.
• In April 2024, 37 samples were submitted to an umpire laboratory, Intertek
Genalysis in Perth. The results were compared to the original assay results
from ALS laboratories for the key analytes of interest to the project. There
was no observable bias between the original assays completed by ALS and the
checks completed by Intertek Genalysis Perth.
• There are 14 duplicates collected over the entire project drilling campaign.
• Assays for the 63 drillholes were completed at ALS.
Verification
of sampling
and assaying
• The verification of
significant
intersections by
either independent
or alternative
company personnel.
• Victory’s representative Prof Kenneth Collerson (PhD, FAusIMM) undertook
verification of significant intersections.
• The use of twinned
holes.
• Eleven percussion (air core and RC) drillholes have been twinned with
diamond drilling (DD001 to DD011). Samples were submitted to the
laboratory for analysis only where the initial screening by handheld pXRF
satisfied the anomalous value threshold as set by company policy, whereas
the diamond drilling was sampled and assayed along the entire length of the
drillhole.
• QQ plots were prepared between the percussion and diamond assays paired
at 5m, with good correlation between the two drillhole types.
• Documentation of
primary data, data
entry procedures,
data verification,
data storage
(physical and
electronic)
protocols.
• ALS laboratories routinely re-assayed anomalous assays as part of their
normal QAQC procedures
• Discuss any
adjustment to assay
data.
• REO assay results were adjusted to convert elemental values to the oxide
equivalent for REOs. The oxide stoichiometric conversion factors used are
provided below:
Location of
data points
• Accuracy and quality
of surveys used to
locate drillholes
(collar and
downhole surveys),
trenches, mine
workings and other
locations used in
Mineral Resource
estimation.
• 51% of the drillholes were surveyed by RTK/DGPS. The remaining holes were
surveyed by handheld GPS with a horizontal accuracy of +/- 5 m. Elevation
values (Z) were assigned from the topography surface where no DGPS data
was available.
• There were no downhole surveys completed. Drillholes were both vertical
and inclined. The majority of drill intervals (99%) were to a drill hole depth of
less than 100m. Downhole survey was completed for the diamond drillholes.
• Specification of the
grid system used.
• All coordinates are in GDA94 Zone 50.
Page 6 of 18
Criteria
JORC Code
explanation
Commentary
• Quality and
adequacy of
topographic control.
• A LiDAR based DEM has been produced for the project.
Data spacing
and
distribution
• Data spacing for
reporting of
Exploration Results.
• The dril
Share your feedback
Discover