Significant North Stanmore Grade Increases in Dy and Tb
Released
Released
Announcement PDF
ASX RELEASE
2 1 O c t o b e r 2 0 2 5
ACN: 124 279 750 E: info@victorymetalsaustralia.com D: +61 (08) 6555 2950 A: Suite 1, 295 Rokeby Road, Subiaco, WA, 6008
— T H E F U T U R E O F A U S T R A L I A N R A R E E A R T H S —
Significant North Stanmore Grade Increases in
Heavy Rare Earths Terbium & Dysprosium
Victory Metals Limited (ASX:VTM) ("Victory" or "the Company") is pleased to report that simple,
low-cost size-by-fraction separation (-10.8 µm) on ore from the North Stanmore Project located in
Western Australia has delivered substantial grade improvements in three critical elements directly
linked to China’s latest bans on defence and high-tech supply chains: Terbium (Tb), Dysprosium (Dy)
and Scandium (Sc).
HIGHLIGHTS
• Simple beneficiation and straightforward -10.8 µm cyclosizing (no complex reagents or
expensive circuits) materially enriches key critical elements
• Terbium (Tb) 53% increase, Dysprosium (Dy) 25% increase & Scandium (Sc) 100% increase
• All three elements are captured by the 1 December 2025 Chinese export ban where
military end-use is implicated, underscoring their strategic importance and the need for
non-Chinese supply
• Rapidly strengthening ex-China pricing since Victory’s March Scoping Study1:
o Terbium US$3,600/kg
o Dysprosium US$850/kg2
• Pre-concentrating the -10.8 µm fines stream can reduce downstream tonnage and
potentially lower reagent consumption
Victory’s Chief Executive Officer and Executive Director Brendan Clark commented: “This is
an incredible outcome at a time when the world’s understanding of the importance of these critical
and strategic minerals is rapidly growing. With a simple and low-cost size fractionation step, we’ve
delivered significant grade increases in three of the world’s most strategically important elements,
Terbium, Dysprosium and Scandium.
As governments move to secure non-Chinese supply amid China’s proposed export bans on these
elements due to their important role in military, projects like North Stanmore become even more
critical. Our results show we can concentrate the value upfront, potentially lowering operating costs
and boosting payables.”
1
Refer to ASX announcement dated 12 March 2025 titled “Outstanding North Stanmore Scoping Study Delivered”
2
September 2025 Benchmark CIF Europe Dy2O3, 99-99.5% USD/tonne, Tb4O7, 99-99.9% USD/tonne
ACN: 124 279 750 E: info@victorymetalsaustralia.com D: +61 (08) 6555 2950 A: Suite 1, 295 Rokeby Road, Subiaco, WA, 6008
— T H E F U T U R E O F A U S T R A L I A N H E A V Y R A R E E A R T H S —
SIZE BY FRACTION BENEFICIATION
ALS Metallurgy Perth, Western Australia carried out simple wet classification to isolate the -10.8 µm
fraction by cyclosizing from a bulk sample composited from the North Stanmore resource area3.
Grades were assayed on head and fraction products. No chemical upgrading or complex mineral
separation was applied.
Feed Grade
(ppm)
<10.8 µm
Fraction (ppm)
Percent
Change (%)
Tb4O7 8 13 >50.0
Dy2O3 55 73 >33.3
Sc2O3 46 92 >100.0
TREO 1484 2104 >41.8
HREO/TREO 0.43 0.41 <-3.2
HREO – Eu2O3, Gd2O3, Tb4O7, Dy2O3, Ho2O3, Er2O3, Tm2O3, Yb2O3, Lu2O3 and Y2O3
Cyclosizing the feed ore to a <10.8 µm fraction resulted in a 42% increase in grade, a 50% increase in
Tb4O7, a 33% increase in Dy2O3, and a 100% increase in Sc2O3. The HREO/TREO ratio remained
essentially constant at 41%.
Results demonstrate intrinsic deportment of key critical elements into ultra fine particles. This ~73%
decrease in mass to be processed provides a low-capex, low-opex front-end upgrade option that
reduces throughput of less critical elements and gangue materials.
DEFENCE USES FOR TERBIUM, DYSPROSIUM & SCANDIUM
Terbium (Tb)
• Essential component of in high-temperature permanent magnets (NdFeB) used in hypersonic
missiles, fighter jet actuators, submarine systems, drones, radar, sonar and guidance systems.
• Provides thermal stability and strength for weapons grade magnetics.
Dysprosium (Dy)
• Critical additive to increase coercivity and temperature in permanent magnets, enabling
them to operate under extreme heat and stress.
• Used in EV traction motors, defence aircraft, naval propulsion, precision guided munitions
and missile defence systems.
Scandium (Sc)
• When alloyed with aluminium, produces lightweight, high-strength Al-Sc alloys for aerospace
frames, fighter jets, naval vessels, and advanced defence structures.
• Improves fuel efficiency and durability in military aircraft.
• Also used in solid oxide fuel cells relevant to military energy resilience.
CHINA’S MINISTRY OF COMMERCE (MOFCOM) EXPORT CONTROL
On 9 October 2025, MOFCOM expanded China’s export control regime on rare earths and related
technologies.
3 Refer to ASX announcement dated 11 August 2025 titled “UPDATED MRE IDENTIFIES HREO/TREO RATIOS UP TO 83%”
ACN: 124 279 750 E: info@victorymetalsaustralia.com D: +61 (08) 6555 2950 A: Suite 1, 295 Rokeby Road, Subiaco, WA, 6008
— T H E F U T U R E O F A U S T R A L I A N H E A V Y R A R E E A R T H S —
Under the new measures (Announcement No. 61 of 2025), export licensing is now required for rare
earths, downstream products and technologies that incorporate Chinese-origin material, with the
rules explicitly prohibiting approvals for military end-uses. The regulations take effect from 1
December 2025, with immediate restrictions already in place for Chinese-origin items.
Terbium, Dysprosium and Scandium, all included on China’s April 2025 controlled list, are now
effectively off limits to foreign military applications, a position reaffirmed in the October update.
• Export licences are in principle denied for foreign military users, giving China unprecedented
leverage over supply chains for strategic defence and high-tech materials.
• The updated rules extend extraterritorial reach with any product manufactured abroad
containing more than 0.1% by value of Chinese-origin rare earths (including terbium,
dysprosium, scandium, and others) will require a Chinese licence before export4.
This announcement has been authorised by the Board of Victory Metals Limited.
For further information please contact:
Brendan Clark Ben Creagh
CEO and Executive Director Investor and Media Relations
info@victorymetalsaustralia.com benc@nwrcommunications.com.au
Victory Metals Limited
Victory is dedicated to the exploration and development of its flagship North Stanmore Heavy Rare
Earth Elements (HREE), Scandium, Hafnium and Gallium Project located in the Cue Region of Western
Australia. The Company is committed to advancing this world-class project to unlock its significant
potential.
In August 2025, Victory Metals announced a robust Mineral Resource Estimate (MRE) for North
Stanmore, totalling 320.6 million tonnes, with the majority of the resource, classified in the indicated
category. This positions the North Stanmore Project as Australia's largest indicated clay heavy rare
earth resource, underscoring its pivotal role as a future supplier of critical materials for the future.
North Stanmore Mineral Resource Estimate
Table 1: North Stanmore August 2025 MRE (≥330ppm TREO + Sc2O3 cut-off grade)
CLASSIFICATION
MRE TONNES
(t)
TREOSc
(ppm)
TREO
(ppm)
HREO
(ppm)
LREO
(ppm)
HREO/TREO
(%)
Sc2O3
(ppm)
Ga2O3
(ppm)
INDICATED 176,522,000 532 505 190 316 39 26 26
INFERRED 144,118,000 484 463 166 297 37 21 25
TOTAL 320,640,000 510 486 179 307 38 24 26
Numbers are rounded to reflect they are an estimate. Numbers may not sum due to rounding.
4
Refer to https://www.mofcom.gov.cn/zwgk/zcfb/art/2025/art_7fc9bff0fb4546ecb02f66ee77d0e5f6.html
ACN: 124 279 750 E: info@victorymetalsaustralia.com D: +61 (08) 6555 2950 A: Suite 1, 295 Rokeby Road, Subiaco, WA, 6008
— T H E F U T U R E O F A U S T R A L I A N H E A V Y R A R E E A R T H S —
Competent Person Statement - Professor Ken Collerson
Statements contained in this report relating to exploration results, Mineral Resource Estimate,
metallurgy results, scientific evaluation, and potential, are based on information compiled and
evaluated by Emeritus Professor Ken Collerson. Professor Collerson (PhD) Principal of KDC Geo
Consulting and Director of Victory Metals Limited, and a Fellow of the Australasian Institute of
Mining and Metallurgy (AusIMM No. 100125), is a geochemist/geologist with sufficient relevant
experience in relation to rare earth element and critical metal mineralisation being reported on, to
qualify as a Competent Person as defined in the Australian Code for Reporting of Identified Mineral
resources and Ore reserves (JORC Code 2012). Professor Collerson consents to the use of this
information in this report in the form and context in which it appears.
APPENDIX 1: 2012 JORC CODE - TABLE 1
Section 1: Sampling Techniques and Data
Criteria
JORC Code
explanation
Commentary
Sampling
techniques
• Nature and
quality of
sampling (e.g. cut
channels, random
chips, or specific
specialised
industry standard
measurement
tools appropriate
to the minerals
under
investigation,
such as downhole
gamma sondes,
or handheld XRF
instruments, etc.).
These examples
should not be
taken as limiting
the broad
meaning of
sampling.
• Include reference
to measures taken
to ensure sample
representivity and
the appropriate
calibration of any
measurement
tools or systems
used.
• Aspects of the
determination of
mineralisation
that are Material
to the Public
Report. In cases
where ‘industry
standard’ work
has been done
this would be
relatively simple
(e.g. ‘reverse
circulation drilling
was used to
obtain 1 m
samples from
which 3 kg was
pulverised to
produce a 30 g
charge for fire
assay’). In other
cases, more
explanation may
be required, such
as where there is
• The North Stanmore drilling that contributed to the July 2025 MRE is shown as
follows -
• (AC) holes were drilled vertically and spaced 100m apart along 200m - 400m
spaced drill lines.
• (AC) drilling samples were collected as 1-m samples from the rig cyclone. Each
sample was placed into large green drill bags (900mmx600mm) for temporary
storage onsite.
• Each sample was then split using a 3-tier (87.5% - 12.5%) splitter and the split
sample was placed into calico sample bags for transport to Perth.
• Sample weights and recoveries were recorded on site and weighed 1.5 - 2.5 kg
depending on the sample recovery from the drill hole. The mean bulk sample
weight was 8.45kg.
• A reputable commercial transport company was used to transport the bags.
• A handheld pXRF analyzer (Olympus Vanta) was used to determine anomalous
REO (Rare earth element) geochemistry (La, Ce, Pr, Nd and Y) from the 1-m
sample piles. pXRF reading times were 45 secs over 3 cycles for multielement
and REO assays. These results are not considered dependable without calibration
using chemical analysis from an accredited laboratory. However, their integrity
was checked using Certified REO -bearing geochemical standards.
• The handheld pXRF is used as a guide to the relative presence or absence of
certain elements, including REOs vectors (La, Ce, Pr, Nd and Y) to help direct the
sampling program. Anomalous 1m samples were then transported to the assay
lab for analysis by Victory personnel. REO anomalism thresholds are determined
by VTM technical lead based on historical data analysis
• Victory attended North Stanmore to collect the green sample bag which was
transported by Victory to Victory’s secure warehouse in Perth.
• Measures taken to ensure sample representivity included regular cleaning of the
rig between drill holes using compressed air and weighing the bulk sample to
ensure reasonable sample return against an expected target weight.
• RC drill samples were collected as 1-m samples from the rig cyclone and placed
on top of black plastic, that was laid on the natural ground surface to prevent
contamination, in separate piles and in orderly rows. A hand-held trowel was
used to collect 4-m composite samples from the 1-m piles. Compositing did not
account for lithology changes. These composite samples weighed between 2 and
3 kg.
Criteria
JORC Code
explanation
Commentary
coarse gold that
has inherent
sampling
problems.
Unusual
commodities or
mineralisation
types (e.g.
submarine
nodules) may
warrant disclosure
of detailed
information
Drilling
techniques
• Drill type (e.g.
core, reverse
circulation, open-
hole hammer,
rotary air blast,
auger, Bangka,
sonic, etc.) and
details (e.g. core
diameter, triple or
standard tube,
depth of diamond
tails, face-
sampling bit or
other type,
whether core is
oriented and if so,
by what method,
etc.).
• (AC) drilling uses a three bladed steel or tungsten drill bit to penetrate the
weathered layer of loose soil and rock fragments. The drill rods are hollow and
feature an inner tube with an outer barrel (similar to RC drilling).
• (AC) drilling uses small compressors (750 cfm/250 psi) to drill holes into the
weathered layer of loose soil and fragments of rock.
• (RC) Drilling used a 5½” face sampling hammer with 1,350cfm/500 psi onboard
compressor, which was occasionally supplemented with an additional booster
(2,100cfm/1,000 psi).
• After drilling is complete, an injection of compressed air is unleashed into the
space between the inner tube and the drill rods inside wall, which flushes the
cuttings up and out of the drill hole through the rod’s inner tube, causing less
chance of cross-contamination.
• (AC) Drilling was performed by Seismic Drilling Pty Ltd and Orlando Drilling Pty
Ltd, and the RC drilling was performed by Orlando Drilling Pty Ltd.
• The drill rigs were inspected daily by VTM personnel for safety and rig hygiene
Drill sample
recovery
• Method of
recording and
assessing core
and chip sample
recoveries and
results assessed.
• Measures taken
to maximise
sample recovery
and ensure
representative
nature of the
samples.
• Whether a
relationship exists
between sample
recovery and
grade and
whether sample
bias may have
occurred due to
preferential
loss/gain of
fine/coarse
material.
• The majority of samples were dry and sample recovery was variable, where
excessive water flows were encountered during drilling.
• Representative percussion drillhole samples were collected as 1-metre intervals,
with corresponding chips placed into chip trays and kept for reference at VTM’s
facilities.
• Measures taken to ensure sample representivity and recovery included regular
cleaning of the rig between drill holes using compressed air and weighing the
bulk sample to ensure reasonable sample return against an expected target
weight.
Logging
• Whether core and
chip samples
have been
• All percussion samples in the chip trays were lithologically logged using standard
industry logging software on a notebook computer.
Criteria
JORC Code
explanation
Commentary
geologically and
geotechnically
logged to a level
of detail to
support
appropriate
Mineral Resource
estimation,
mining studies
and metallurgical
studies.
• All (AC) samples have been logged for lithology, alteration, quartz veins, colour,
fabrics.
• All (AC) samples have been analysed by a handheld pXRF.
• All samples were subjected to a NIR spectrometer for the identification of
minerals and the variations in mineral chemistry to detect alteration
assemblages and regolith profiles.
• All geological information noted above has been reviewed by a competent
person as recognised by JORC.
• Whether logging
is qualitative or
quantitative in
nature. Core (or
costean, channel,
etc.)
photography.
• Logging is qualitative in nature.
• (AC) samples have been photographed.
• The total length
and percentage
of the relevant
intersections
logged.
• 90% of the sample intervals were logged.
Subsampling
techniques
and sample
preparation
• If core, whether
cut or sawn and
whether quarter,
half or all core
taken.
• Diamond drilling was PQ core.
• Half core samples were taken, with the exception of when twin samples were
collected and then the samples were quarter core.
• If non-core,
whether riffled,
tube sampled,
rotary split, etc.
and whether
sampled wet or
dry.
• Air core and RC sampling was undertaken on 1m intervals using a Meztke Static
Cone splitter. In the Sampling techniques section above it mentions Riffle
Splitter was used – This is contradictory
• Most 1-metre samples were dry and weighed between 1.5 and 2.5 kgs.
• Samples from the cyclone were placed into green drill bags in laid out in orderly
rows on the ground.
• Using a hand-held trowel, 1m samples were collected from the one-metre drill
bags after splitting of the sample.
• These samples were placed into calico bags and weighed between 1.5 and 2.5
kgs.
• For all sample
types, the nature,
quality and
appropriateness
of the sample
preparation
technique.
• Samples were assayed by ALS Laboratories in Perth, a NATA Accredited Testing
Laboratory. The assay methods used include:
o ME-4ACD81: Four acid digestion followed by ICP-AES measurement
o ME-MS81: Lithium borate fusion followed by acid dissolution and ICP-
AES measurement
o ME-ICP06: Fusion decomposition followed by ICP-AES measurement
• REOs were all analysed by ME-MS81 (four acid digestion followed by ICP-AES
measurement) with results returned in their elemental form. Elements were
then converted to oxides using the appropriate stoichiometric conversion
factors.
• Base metals are assayed by ME-ICP06: Fusion decomposition.
• Non-ferrous metals are assayed by ME-4ACD81: Four acid digestion.
• Quality control
procedures
adopted for all
subsampling
stages to
maximise
• Using a riffle splitter, 1m composite samples were collected from the individual
sample bags.
• Quality control of the assaying comprised the collection of a bulk repeat sample
every hole, along with the regular insertion of industry (OREAS) standards
(certified reference material) every 20 samples and blanks (beach sand) every 50
samples. The repeat sample was collected by passing the bulk reject obtained
Criteria
JORC Code
explanation
Commentary
representivity of
samples.
from the first split stage through the riffle splitter once more. The repeat sample
is not a duplicate.
• Measures taken
to ensure that the
sampling is
representative of
the in-situ
material
collected,
including for
instance results
for field
duplicate/second-
half sampling.
• Fourteen twin samples of quarter core (diamond PQ) were compared to the
original sample for each REO element and results were found to be acceptable.
• Whether sample
sizes are
appropriate to the
grain size of the
material being
sampled.
• Composite samples weighed between 1 and 2 Kg’s.
• Sample sizes are considered appropriate to the grain size of the material being
sampled.
Quality of
assay data
and
laboratory
tests
• The nature,
quality and
appropriateness
of the assaying
and laboratory
procedures used
and whether the
technique is
considered partial
or total.
• All samples were analysed in the field using a handheld Olympus Vanta XRF unit
to identify geochemical thresholds. These results are not considered dependable
without calibration using chemical analysis. They were used as a guide to the
relative presence or absence of certain elements, including REOs to help guide
the drill program and which samples were submitted for analytical analysis.
• All pXRF anomalous samples were sent to ALS Wangara in Perth for analysis.
Over time the mineralised sample criteria has evolved from an initial sampling
threshold value of La+Ce+Nd+Pr+Y > 200ppm (for the RSC MRE), to Ce>30ppm
(for the post RSC to July 2024 MRE), and most recently Y>30ppm (POST July 2024
to January 2025 MRE).
• Samples were submitted for sample preparation and geochemical analysis by
ALS in Wangara, Perth, a NATA accredited laboratory. All samples were crushed
and pulverized to generate a pulp aliquot sample with 95% of the aliquot sample
passing 75µ (ALS methods CRU-31, PUL-31). Aliquots were analysed using the
following methods:
o Lithium borate fusion prior to acid dissolution and ICP-AES (ALS
method ME-MS81, a total assay technique) for Ba, Ce, Cr, Cs, Dy, Er,
Eu, Ga, Gd, Hf, Ho, La, Lu, Nb, Nd, Pr, Rb, Sc, Sm, Sn, Sr, Ta, Tb, Th, Ti,
Tm, U, V, W, Y, Yb, and Zr.
o Lithium borate fusion prior to acid dissolution and ICP-AES (ALS
method ME-ICP06, a total assay technique) for Al2O3, BaO, CaO,
Cr2O3, Fe2O3, K2O, MgO, MnO, Na2O, P2O5, SiO2, SrO, TiO2, and
Total.
o 4-acid digest and read by ICP-AES (ALS method ME-4ACD81, a partial
assay technique) for Ag, As, Cd, Co, Cu, Li, Mo, Ni, Pb, Sc, Tl, and Zn
(base metals).
o Thermogravimetric analysis to determine loss on ignition (LOI)
content.
• The sample preparation and analysis are considered appropriate for the
analytes.
• As a result of the pXRF analysis leading the selection criteria for assaying by a
laboratory, only 16,620 metres of drilling of the total 45,340 drill metres (or 37%
of total metres) has been assayed.
• For geophysical
tools,
spectrometers,
handheld XRF
instruments, etc.,
the parameters
• At Victory’s Perth facility spot checks were completed on selected samples using
a handheld Olympus Vanta XRF unit. The pXRF device was used to determine
anomalous REO geochemistry (La, Ce, Nd, Pr and Y) from the 1-m sample piles.
• pXRF reading times were 45 secs over 3 beams for multielement and REO assays.
These results are not considered dependable without calibration using chemical
Criteria
JORC Code
explanation
Commentary
used in
determining the
analysis including
instrument make
and model,
reading times,
calibrations
factors applied
and their
derivation, etc.
analysis from an accredited laboratory. However, their analytical accuracy was
checked using REO -bearing geochemical standards.
• The pXRF results were not used for estimation.
• Nature of quality
control
procedures
adopted (e.g.
standards, blanks,
duplicates,
external
laboratory
checks) and
whether
acceptable levels
of accuracy (i.e.
lack of bias) and
precision have
been established.
• Sample weights were measured for 174 of the AC drillholes, and recovery was
measured for 7 of the diamond drillholes. Sample recovery for the diamond
drillholes recovery was 100 %. Based on the information available, sample
recovery is acceptable for the diamond holes. The discrepancy between the
target weight and the measured weight for the air-core samples indicates
potential for bias, however, there may have been an issue with the target
weight, and this should be reassessed.
• Assay analytical precision was established by laboratory repeats and was
deemed acceptable to the Competent Person/s.
• The overall performance of standards was deemed to be acceptable, see Error!
Reference source not found..
o It was noted that La, Pr, Ce and Eu in the CRM OREAS464 have
expected values above the detection limits of the lab method
ME_MS81.
o It was noted that Co and Ni in the CRMs OREAS461 and OREAS464 are
over reported against the expected values using the lab method
ME_4ACD81.
o It was noted that Cu and Sc in the CRM OREAS464 are under reported
against the expected values using the lab method ME_4ACD81.
• The overall performance of the blanks was deemed to be acceptable, see Error!
Reference source not found..
• Field diamond duplicate data points taken from the same drillholes is available
only for 14 samples from diamond drill core. The mean grade of the original
sample was generally reproduced by the duplicate for the various analytes and is
acceptable to the Competent Person/s.
• In April 2024, 37 samples were submitted to an umpire laboratory, Intertek
Genalysis in Perth. The results were compared to the original assay results from
ALS laboratories for the key analytes of interest to the project. There was no
observable bias between the original assays completed by ALS and the checks
completed by Intertek Genalysis Perth.
• Twinned hole results are discussed in the relevant section below.
• There are only 14 duplicates collected over the entire project drilling campaign.
MEC recommends that future drilling campaigns will require an increase in
duplicate samples to be collected to demonstrate the lack of sample bias in the
rig-mounted splitter.
Verification
of sampling
and assaying
• The verification of
significant
intersections by
either
independent or
alternative
company
personnel.
• Victory’s representative Prof Kenneth Collerson (PhD, FAusIMM) undertook
verification of significant intersections.
• The use of
twinned holes.
• Eleven percussion (air core and RC) drillholes have been twinned with diamond
drilling (DD001 to DD011). Samples were submitted to the laboratory for analysis
only if the initial screening by handheld pXRF satisfied the anomalous value
threshold as set by company policy, whereas the diamond drilling was sampled
and assayed along the entire length of the drillhole.
Criteria
JORC Code
explanation
Commentary
• QQ plots were prepared between the percussion and diamond assays paired at
5m, with good correlation between the two drillhole types.
• Documentation of
primary data, data
entry procedures,
data verification,
data storage
(physical and
electronic)
protocols.
• ALS laboratories routinely re-assayed anomalous assays as part of their normal
QAQC procedures
• Discuss any
adjustment to
assay data.
• REO assay results were adjusted to convert elemental values to the oxide
equivalent for REOs. The stoichiometric conversion factors used are provided
below:
Element Oxide Element to stoichiometric oxide conversion factor
Ce (Cerium) CeO2 1.2284
Dy (Dysprosium) Dy2O3 1.1477
Er (Erbium) Er2O3 1.1435
Eu (Europium) Eu2O3 1.1579
Ga (Gallium) Ga2O3 1.3442
Gd (Gadolinium) Gd2O3 1.1526
Ho (Holmium) Ho2O3 1.1455
La (Lanthanum) La2O3 1.1728
Lu (Lutetium) Lu2O3 1.1371
Nd (Neodymium) Nd2O3 1.1664
Pr (Praseodymium) Pr6O11 1.2082
Sc (Scandium) Sc2O3 1.5338
Sm (Samarium) Sm2O3 1.1596
Tb (Terbium) Tb4O7 1.1762
Tm (Thulium) Tm2O3 1.1421
Y (Yttrium) Y2O3 1.2699
Yb (Ytterbium) Yb2O3 1.1387
Location of
data points
• Accuracy and
quality of surveys
used to locate
drillholes (collar
and downhole
surveys),
trenches, mine
workings and
other locations
used in Mineral
Resource
estimation.
• 51% of the drillholes were surveyed by RTK/DGPS. The remaining holes were
surveyed by handheld GPS with a horizontal accuracy of +/- 5 m. Elevation values
(Z) were assigned from the topography surface where no DGPS data was
available.
• There were no downhole surveys completed. Drillholes were both vertical (92%)
and inclined (8%). The majority of drill intervals (99%) were less than a drill hole
depth of 100m.
• Specification of
the grid system
used.
• All coordinates are in GDA94 Zone 50.
• Quality and
adequacy of
topographic
control.
• A three second SRTM Digital Elevation Model was used to represent the
topographical surface sourced from Geoscience Australia. The topography was
adjusted by using the DGPS surveyed collar coordinates to model a more
accurate topographical surface. It is recommended that a LiDAR based DEM is
used in future.
Data spacing
and
distribution
• Data spacing for
reporting of
Exploration
Results.
• The drillhole spacing at North Stanmore ranges from 50 x 50m to 250 x 100m.
• Whether the data
spacing, and
distribution is
sufficient to
establish the
• Given the nature of the exploration programs, the spacing of the exploration
drilling is appropriate for understanding the exploration potential and the
identification of structural controls on the mineralisation. In areas of closer
spaced drilling the spacing demonstrates grade and geological continuity
sufficient to support Indicated Mineral Resources. Where drillhole spacing
Criteria
JORC Code
explanation
Commentary
degree of
geological and
grade continuity
appropriate for
the Mineral
Resource and Ore
Reserve
estimation
procedure(s) and
classifications
applied.
increases, grade and geological continuity can be implied and has been classified
as an Inferred Mineral Resource. Areas where the drillhole spacing is such that
grade and geological continuity cannot be implied, have been excluded from the
Mineral Resource.
• The applied Mineral Resource classification is commensurate with the grade
continuity demonstrated.
• Whether sample
compositing has
been applied.
• Percussion samples were collected as 1.0 m samples. Core was collected at a
nominal 1.0 m samples. Air core samples were collected as 1.0 m and 4.0 m
samples.
Orientation
of data in
relation to
geological
structure
• Whether the
orientation of
sampling
achieves
unbiased
sampling of
possible
structures and the
extent to which
this is known,
considering the
deposit type.
• Mineralisation is sub horizontal, as such the vertical drillholes are suitable to test
mineralisation thickness.
• It is concluded from aerial magnetics that the mineralisation trends 010°-030°.
• Air core drilling was vertical as the mineralisation is interpreted to be sub parallel
to the regolith profile. RC percussion drilling was angled.
• Downhole widths of mineralisation are known with percussion drilling methods
to +/- 1 metre.
• If the relationship
between the
drilling
orientation and
the orientation of
key mineralised
structures is
considered to
have introduced a
sampling bias,
this should be
assessed and
reported if
material.
• Mineralisation is sub-horizontal. Azimuths and dips of drilling was designed to
intersect the strike of the rocks at right angles.
Sample
security
• The measures
taken to ensure
sample security.
• All samples were packaged and managed by VTM personnel.
• Larger packages of samples were couriered to Core from Cue by professional
transport companies in sealed bulka bags.
• Unused samples from the percussion drilling are stored at Victory’s secure
warehouse in Perth.
Audits or
reviews
• The results of any
audits or reviews
of sampling
techniques and
data.
• MEC conducted an audit of the project data and the historic MRE in April of
2024. The findings were as follows -
o Several validation issues have now been corrected in the drillhole
database, and the data is of sufficient quality to inform an Indicated
and Inferred mineral resource.
o There are no downhole surveys so there is a risk of the hole paths
deviating from planned, particularly with the deeper drillholes >10
Share your feedback