BREAKTHROUGH HEAVY RARE EARTH RECOVERY PATHWAY TO PRODUCTION
Released
Released
Announcement PDF
ASX: VTM Victory Metals Limited ACN 124 279 750
Suite 1, 295 Rokeby Road, Subiaco Western Australia 6008
Email: admin@victorymetalsaustralia.com www.victorymetalsaustralia.com Page 1 of 7
BREAKTHROUGH HEAVY RARE EARTH
RECOVERY PATHWAY TO PRODUCTION
Victory Metals Limited (ASX:VTM) is pleased to announce these exceptional
metallurgical leaching test results from its flotation concentrate at the 100%-owned
North Stanmore Heavy Rare Earth Project in Western Australia.
The test work was conducted on concentrate produced from the Company’s recent
flotation program, which achieved a 48× upgrade to 5.9% TREO while rejecting
approximately 95% of the feed mass into tailings. The subsequent leaching of this
concentrate has delivered >70% extraction of the critical heavy rare earths Dysprosium,
Terbium and Yttrium in standard agitated leach tank conditions.
These results represent a significant technical and economic breakthrough.
HIGHLIGHTS
• Outstanding leaching results from North Stanmore flotation concentrate
delivering high-value Heavy Rare Earth Elements 70.9% Dysprosium (Dy), 70.2%
Terbium (Tb) and 75.1% Yttrium (Y)
• Results achieved using low acid consumption and standard agitated leach tank
conditions at atmospheric pressure.
• This process sets Victory apart from peers that have reported flotation results and
require high-temperature acid cracking (~400–500°C) with very high sulphuric
acid consumption (~1,500 kg/t of concentrate)
• The results were obtained without the traditional acid-cracking process, avoiding
an estimated ~$1 billion in associated capital expenditure based on recent peers
CAPEX requirements.1
• Victory plans on selling its heavy rare earth concentrate into the Global market
resulting in:
o Faster & simpler path to market
o Low CAPEX & OPEX
o Unique Heavy Rare Earth Enriched Concentrate with negligible
amounts of deleterious elements
• Combined with recent flotation work (48× TREO upgrade to 5.9% TREO with ~95%
mass rejection), the flowsheet enables small scale, low capex hydrometallurgical
circuits that Victory proposes will be operated by third party off takers 2
1
Refer to https://www.arultd.com/projects/nolans/project-update/, https://www.iluka.com/media/jp1mawlt/2025-full-year-results-presentation.pdf
2
Refer to ASX announcement dated 3rd
March 2026 titled “48x Rare Earth Upgrade to 5.9% TREO.
ASX ANNOUNCEMENT 01 APR 2026
Page 2 of 7
Victory Metals Chief Executive Officer and Executive Director Brendan Clark
commented: “These outstanding test results highlight that the concentrate at North
Stanmore is truly something special. There is nothing like it in the western world, and
we expect high demand as a result. The fact we can separate out the valuable
elements without high temperatures and high acid consumption puts us at a
significant advantage to peers. Our product can be shipped as general cargo with
significant ratios of the rare earths that matter and that the Western world needs:
Dysprosium, Terbium and Yttrium.”
Yttrium is now being reported with sales in North America surpassing $1,000 US per
kg and, with Victory containing over 23% Yttrium in our concentrate and the Yttrium
market being totally controlled by China, this positions Victory as a future leader of
the heavy rare earth sector.
Being able to achieve this at low cost and without the expenditure on billion-dollar
plants that peers need to process their concentrates sets Victory apart from our peers.
Our plan is to develop a simple, low-cost flotation circuit and sell our concentrate
directly to Western markets. This is a proven yet simple, low cost and fast path to
market.
Further optimisation, variability test work and detailed flowsheet development are
underway and will be reported as results become available.”
Metallurgical Process & Performance
Standard Hydrometallurgical Circuit
Victory has successfully completed a definitive 8-hour leaching test on the high-grade
flotation concentrate (~5.9% TREO) generated from North Stanmore ore (see ASX
announcement 03MAR26). To ensure commercial scalability and minimize technical
risk, the leaching was conducted at ALS Metallurgy (Balcatta, WA) using simulated
standard hydrometallurgical agitated tanks.
The use of agitated tank leaching—rather than high-pressure autoclaves or complex
acid-cracking kilns—demonstrates a highly conventional and de-risked flowsheet. The
process utilized low-concentration HCl (<6% HCl solution) at atmospheric pressure and
a temperature of 90°C, achieving high extractions. This confirms that North Stanmore
can move toward production using off-the-shelf processing technology.
Key Results: Exceptional HRE Extraction
The leaching test confirmed that the secondary phosphate minerals (rhabdophane
and churchite) concentrated during flotation are highly amenable to mild acid
leaching. Key results (see Figure 1 and Table 1) show excellent selective extraction, with
significantly higher recoveries of high-value heavy rare earth elements (HREEs) and
relatively lower recoveries of light rare earth elements (LREEs).
Page 3 of 7
• Exceptional extraction rates: Extraction rates are consistent with previous
whole-of-ore testing but now applied to a significantly smaller volume of
material (flotation concentrate).
• High Selectivity: This selective metallurgy is a major positive for Victory. Potential
off-take partners have specifically requested minimal light rare earth content.
The strong extraction of heavy rare earths, coupled with lower light rare earth
recoveries, is highly advantageous as LREEs are abundant in global supply
chains and are of lower value.
• Low Impurity Profile: The flotation concentrate contains only 274 ppm Thorium
and 70 ppm Uranium, well below the thresholds for hazardous radioactive
classification. This supports the Company’s strategy to ship concentrate as
General Cargo.
Figure 1. Graph showing the increased extraction of Heavy Rare Earths vs Light Rare Earths.
Page 4 of 7
Rare Earth Element % Extraction
La 46.5
Ce 49.5
Pr 48.0
Nd 49.2
Sm 56.1
Eu 61.8
Gd 66.3
Tb 70.2
Dy 70.9
Ho 75.4
Er 74.8
Tm 76.4
Yb 74.1
Lu 74.9
Y 75.1
Table 1. Table of the individual elemental extraction %.
Figure 2. Float Feed TREO assemblage
Page 5 of 7
Figure 3. Float concentrate (leach feed) TREO assemblage.
Figure Figure 4. Leach liquor TREO assemblage.
Page 6 of 7
This announcement has been authorised by the Board of Victory Metals Limited.
For further information please contact:
Brendan Clark Jim Carden
CEO and Executive Director Investor and Media Relations
admin@victorymetalsaustralia.com jimc@bastionagency.com
Victory Metals Limited
Victory is dedicated to the exploration and development of its flagship North Stanmore
Heavy Rare Earth Elements (HREE), Scandium, Hafnium and Gallium Project located
in the Cue Region of Western Australia. The Company is committed to advancing this
world-class project to unlock its significant potential.
In August 2025, Victory Metals announced a robust Mineral Resource Estimate (MRE)
for North Stanmore, totalling 320.6 million tonnes, with the majority of the resource,
classified in the indicated category. This positions the North Stanmore Project as
Australia's largest indicated clay heavy rare earth resource, underscoring its pivotal role
as a future supplier of critical materials for the future.
North Stanmore Mineral Resource Estimate
Table 1: North Stanmore August 2025 MRE (≥330ppm TREO + Sc2O3 cut-off grade)
CLASSIFICATION
MRE TONNES
(t)
TREOSc
(ppm)
TREO
(ppm)
HREO
(ppm)
LREO
(ppm)
HREO/TREO
(%)
Sc2O3
(ppm)
Ga2O3
(ppm)
INDICATED 176,522,000 532 505 190 316 39 26 26
INFERRED 144,118,000 484 463 166 297 37 21 25
TOTAL 320,640,000 510 486 179 307 38 24 26
Numbers are rounded to reflect they are an estimate. Numbers may not sum due to rounding.
Page 7 of 7
Forward-looking statements
This announcement contains “forward-looking statements”. All statements other than
those of historical facts included in this announcement are forward looking
statements. Where a company expresses or implies an expectation or belief as to
future events or results, such expectation or belief is expressed in good faith and
believed to have a reasonable basis. However, forward-looking statements are subject
to risks, uncertainties and other factors, which could cause actual results to differ
materially from future results expressed, projected or implied by such forward-looking
statements. Such risks include, but are not limited to, metals price volatility, currency
fluctuations, increased production costs and variances in ore grade or recovery rates
from those assumed in mining plans, as well as political and operational risks and
governmental regulation and judicial outcomes. Neither company undertakes any
obligation to release publicly any revisions to any “forward-looking” statement.
Competent Person Statement - Professor Ken Collerson
Statements contained in this report relating to exploration results, Mineral Resource
Estimate, metallurgy results, scientific evaluation, and potential, are based on
information compiled and evaluated by Emeritus Professor Ken Collerson. Professor
Collerson (PhD) Principal of KDC Geo Consulting and Director of Victory Metals
Limited, and a Fellow of the Australasian Institute of Mining and Metallurgy (AusIMM
No. 100125), is a geochemist/geologist with sufficient relevant experience in relation to
rare earth element and critical metal mineralisation being reported on, to qualify as a
Competent Person as defined in the Australian Code for Reporting of Identified
Mineral resources and Ore reserves (JORC Code 2012). Professor Collerson consents to
the use of this information in this report in the form and context in which it appears.
APPENDIX 1: 2012 JORC CODE
Table 1: JORC Code
Section 1: Sampling Techniques and Data
Criteria
JORC Code
explanation
Commentary
Sampling
techniques
• Nature and quality of
sampling (e.g. cut
channels, random
chips, or specific
specialised industry
standard
measurement tools
appropriate to the
minerals under
investigation, such
as downhole gamma
sondes, or handheld
XRF instruments,
etc.). These
examples should not
be taken as limiting
the broad meaning
of sampling.
• Include reference to
measures taken to
ensure sample
representivity and
the appropriate
calibration of any
measurement tools
or systems used.
• Aspects of the
determination of
mineralisation that
are Material to the
Public Report. In
cases where
‘industry standard’
work has been done
this would be
relatively simple
(e.g. ‘reverse
circulation drilling
was used to obtain
1 m samples from
which 3 kg was
pulverised to
produce a 30 g
charge for fire
assay’). In other
cases, more
explanation may be
required, such as
where there is
coarse gold that has
inherent sampling
• Note that at the time of compiling Table 1 and reporting of significant results
that 5 drillholes in the north of the project were still pending assay return,
drillholes 2025IFAC059 to 63.
• (AC) Air core drillholes were drilled vertically and spaced 100m apart along
200m - 400m spaced drill lines.
• (AC) drilling samples were collected as 1-m samples from the rig cyclone. Each
sample was placed into large green drill bags (900mmx600mm) for temporary
storage onsite.
• Each sample was then split using a 3-tier (87.5% - 12.5%) splitter and the split
sample was placed into calico sample bags for transport to Perth.
• Sample weights and recoveries were recorded on site and weighed 1.5 - 2.5
kg depending on the sample recovery from the drill hole. The mean bulk
sample weight was 8.45kg.
• A commercial transport company was used to transport the bags to the
Victory warehouse in Perth.
• A handheld pXRF analyzer (Olympus Vanta) was used to determine
anomalous REO (Rare earth element) geochemistry (La, Ce, Pr, Nd and Y) from
the 1-m sample piles. pXRF reading times were 45 secs over 3 cycles for
multielement and REO assays. These results are not considered dependable
without calibration using chemical analysis from an accredited laboratory.
However, their integrity was checked using Certified REO -bearing
geochemical standards.
• The handheld pXRF is used as a guide to the relative presence or absence of
certain elements, including REOs vectors (La, Ce, Pr, Nd and Y) to help direct
the sampling program. Anomalous 1m samples were then transported to the
assay lab for analysis by Victory personnel. REO anomalism thresholds are
determined by VTM technical lead based on historical data analysis. Currently
the anomaly threshold is plus 30ppm Yttrium.
• Victory attended North Stanmore to collect the green sample bag which was
transported by Victory to Victory’s secure warehouse in Perth.
• Measures taken to ensure sample representivity included regular cleaning of
the rig between drill holes using compressed air and weighing the bulk
sample to ensure reasonable sample return against an expected target
weight.
• RC drill samples were collected as 1-m samples from the rig cyclone and
placed on top of black plastic, which was laid on the natural ground surface to
prevent contamination, in separate piles and in orderly rows. A hand-held
trowel was used to collect 4-m composite samples from the 1-m piles.
Compositing did not account for lithology changes. These composite samples
weighed between 2 and 3 kg.
Criteria
JORC Code
explanation
Commentary
problems. Unusual
commodities or
mineralisation types
(e.g. submarine
nodules) may
warrant disclosure of
detailed information
Drilling
techniques
• Drill type (e.g. core,
reverse circulation,
open-hole hammer,
rotary air blast,
auger, Bangka,
sonic, etc.) and
details (e.g. core
diameter, triple or
standard tube,
depth of diamond
tails, face-sampling
bit or other type,
whether core is
oriented and if so,
by what method,
etc.).
• (AC) drilling uses a three bladed steel or tungsten drill bit to penetrate the
weathered layer of loose soil and rock fragments. The drill rods are hollow
and have an inner tube with an outer barrel (similar to RC drilling).
• (AC) drilling uses small compressors (750 cfm/250 psi) to drill holes into the
weathered layer of loose soil and fragments of rock.
• (RC) Drilling used a 5½” face sampling hammer with 1,350cfm/500 psi
onboard compressor, which was occasionally supplemented with an
additional booster (2,100cfm/1,000 psi).
• After drilling is complete, an injection of compressed air is unleashed into the
space between the inner tube and the drill rods inside wall, which flushes the
cuttings up and out of the drill hole through the rod’s inner tube, resulting in
less chance of cross-contamination.
• (AC) Drilling was conducted by Bostech Drilling for the 63 drillhole
programme.
• The drill rigs were inspected daily by VTM personnel for safety and rig hygiene
Drill sample
recovery
• Method of recording
and assessing core
and chip sample
recoveries and
results assessed.
• Measures taken to
maximise sample
recovery and ensure
representative
nature of the
samples.
• Whether a
relationship exists
between sample
recovery and grade
and whether sample
bias may have
occurred due to
preferential
loss/gain of
fine/coarse material.
• The majority of samples were dry, where excessive water flows were
encountered during drilling the sample recovery was variable. The depth that
water was encountered was recorded in the database.
• Representative percussion drillhole samples were collected as 1-metre
intervals, with corresponding chips placed into chip trays and kept for
reference at VTM’s facilities.
• Measures taken to ensure sample representivity and recovery included
regular cleaning of the rig between drill holes using compressed air and
weighing the bulk sample to ensure reasonable sample return against an
expected target weight.
Logging
• Whether core and
chip samples have
been geologically
and geotechnically
logged to a level of
detail to support
appropriate Mineral
Resource estimation,
mining studies and
metallurgical
studies.
• All percussion samples in the chip trays were lithologically logged using
standard industry logging software on a notebook computer.
• All (AC) samples have been logged for lithology, alteration, quartz veins,
colour, fabrics.
• All (AC) samples have been analysed by a handheld pXRF.
• All samples were subjected to a NIR spectrometer for the identification of
minerals and the variations in mineral chemistry to detect alteration
assemblages and regolith profiles.
• All geological information noted above has been reviewed by a competent
person as recognised by JORC.
• Whether logging is
qualitative or
quantitative in
nature. Core (or
• Logging is qualitative in nature.
• (AC) samples have been photographed.
Criteria
JORC Code
explanation
Commentary
costean, channel,
etc.) photography.
• The total length and
percentage of the
relevant
intersections
logged.
• 90% of the sample intervals were logged.
Subsamplin
g techniques
and sample
preparation
• If core, whether cut
or sawn and whether
quarter, half or all
core taken.
• Diamond drilling was PQ core.
• Half core samples were taken, with the exception of when twin samples were
collected and then the samples were quarter core.
• If non-core, whether
riffled, tube
sampled, rotary split,
etc. and whether
sampled wet or dry.
• Air core and RC sampling was undertaken on 1m intervals using a Meztke
Static Cone splitter.
• Samples from the cyclone were placed into green drill bags and were laid out
in orderly rows on the ground.
• Using a hand-held trowel, 1m samples were collected from the one-metre
drill bags after splitting of the sample.
• These samples were placed into calico bags and weighed between 1.5 and 2.5
kgs.
• For all sample types,
the nature, quality
and appropriateness
of the sample
preparation
technique.
• Samples were assayed by ALS Laboratories in Perth, a NATA Accredited
Testing Laboratory. The assay methods used include:
o ME-4ACD81: Four acid digestion followed by ICP-AES
measurement
o ME-MS81: Lithium borate fusion followed by acid dissolution and
ICPMS measurement
o ME-ICP06: Fusion decomposition followed by ICP-OES
measurement
• REOs were all analysed by ME-MS81 (four acid digestion followed by ICPMS
measurement) with results returned in their elemental form. Elements were
then converted to oxides using the appropriate stoichiometric conversion
factors.
• Base metals are assayed by ME-ICP06: Fusion decomposition.
• Non-ferrous metals are assayed by ME-4ACD81: Four acid digestion.
• Quality control
procedures adopted
for all subsampling
stages to maximise
representivity of
samples.
• Using a riffle splitter, 1m composite samples were collected from the
individual sample bags.
• Quality control of the assaying comprised the collection of a bulk repeat
sample every hole, along with the regular insertion of industry (OREAS)
standards (certified reference material) every 20 samples and blanks (beach
sand) every 50 samples. The repeat sample was collected by passing the bulk
reject obtained from the first split stage through the riffle splitter once more.
The repeat sample is not a duplicate.
• Measures taken to
ensure that the
sampling is
representative of the
in-situ material
collected, including
for instance results
for field
duplicate/second-
half sampling.
• Fourteen twin samples of quarter core (diamond PQ) were compared to the
original sample for each REO element and results were found to be
acceptable to the CP.
• Whether sample
sizes are appropriate
to the grain size of
the material being
sampled.
• Composite samples weighed between 1 and 2 Kg’s.
• Sample sizes are considered appropriate to the grain size of the material
being sampled.
Criteria
JORC Code
explanation
Commentary
Quality of
assay data
and
laboratory
tests
• The nature, quality
and appropriateness
of the assaying and
laboratory
procedures used
and whether the
technique is
considered partial or
total.
• All samples were analysed in the field using a handheld Olympus Vanta XRF
unit to identify geochemical thresholds. These results are not considered
dependable without calibration using chemical analysis. They were used as a
guide to the relative presence or absence of certain elements, including REOs
to help guide the drill program and selection of samples to be submitted for
analytical analysis.
• All pXRF anomalous samples were sent to ALS Wangara in Perth for analysis.
Over time the mineralised sample criteria has evolved from an initial sampling
threshold value of La+Ce+Nd+Pr+Y > 200ppm (for the RSC MRE), to
Ce>30ppm (for the post RSC to July 2024 MRE), and most recently Y>30ppm
(POST July 2024 to July 2025 MRE).
• Samples were submitted for sample preparation and geochemical analysis by
ALS in Wangara, Perth, a NATA accredited laboratory. All samples were
crushed and pulverized to generate a pulp aliquot sample with 95% of the
aliquot sample passing 75µ (ALS methods CRU-31, PUL-31). Aliquots were
analysed using the following methods:
o Lithium borate fusion prior to acid dissolution and ICPMS (ALS
method ME-MS81, a total assay technique) for Ba, Ce, Cr, Cs, Dy,
Er, Eu, Ga, Gd, Hf, Ho, La, Lu, Nb, Nd, Pr, Rb, Sc, Sm, Sn, Sr, Ta, Tb,
Th, Ti, Tm, U, V, W, Y, Yb, and Zr.
o Lithium borate fusion prior to acid dissolution and ICPOES (ALS
method ME-ICP06, a total assay technique) for Al2O3, BaO, CaO,
Cr2O3, Fe2O3, K2O, MgO, MnO, Na2O, P2O5, SiO2, SrO, TiO2, and
Total.
o 4-acid digest and read by ICP-AES (ALS method ME-4ACD81, a
partial assay technique) for Ag, As, Cd, Co, Cu, Li, Mo, Ni, Pb, Sc, Tl,
and Zn (base metals).
o Thermogravimetric analysis to determine loss on ignition (LOI)
content.
• The sample preparation and analysis are considered appropriate for the
analytes.
• As a result of the pXRF analysis leading the selection criteria for assaying by a
laboratory, only 16,620 metres of drilling of the total 45,340 drill metres (or
37% of total metres) has been assayed.
• For geophysical
tools, spectrometers,
handheld XRF
instruments, etc., the
parameters used in
determining the
analysis including
instrument make
and model, reading
times, calibrations
factors applied and
their derivation, etc.
• At Victory’s Perth facility spot checks were completed on selected samples
using a handheld Olympus Vanta XRF unit. The pXRF device was used to
determine anomalous REO geochemistry (La, Ce, Nd, Pr and Y) from the 1-m
sample piles.
• pXRF reading times were 45 secs over 3 beams for multielement and REO
assays. These results are not considered dependable without calibration using
chemical analysis from an accredited laboratory. However, their analytical
accuracy was checked using REO -bearing geochemical standards.
• The pXRF results were not used for estimation.
• Nature of quality
control procedures
adopted (e.g.
standards, blanks,
duplicates, external
laboratory checks)
and whether
acceptable levels of
accuracy (i.e. lack of
bias) and precision
have been
established.
• Sample weights were measured for 174 of the AC drillholes, and recovery was
measured for 7 of the diamond drillholes. Sample recovery for the diamond
drillholes recovery was 100 %. Based on the information available, sample
recovery is acceptable for the diamond holes.
• Assay analytical precision was established by laboratory repeats and was
deemed acceptable to the Competent Person.
• OREAS 464 is a high grade ore, rare earth element (TREO = 5.10%) matrix-
matched certified reference material (MMCRM) prepared and certified by Ore
Research & Exploration. OREAS 461 is an ore grade, rare earth element (TREO
= 1.06%) matrix-matched certified reference material (MMCRM) prepared
and certified by Ore Research & Exploration. The materials constituting
OREAS 464 were sourced from Lynas Corporation’s Mount Weld Project (the
‘Central Lanthanide Deposit’) which is located 35 kilometres south of
Criteria
JORC Code
explanation
Commentary
Laverton in Western Australia. The Mount Weld source materials (waste, low
and medium grade REE ores) were found to be highly hygroscopic to the
extent that significant analytical errors would likely result during analysis
unless strict moisture handling procedures were adhered. To avoid this
complication, the hygroscopic property was destroyed by roasting the
materials at 900°C for 2 hours.
o The overall performance of standards was deemed to be
acceptable. It was noted that Y in the CRM OREAS461 have
expected values above the detection limits of the lab method
ME_MS81. Dy and Tb were within action limits.
o OREAS464 which is a higher grade standard returned good results
within limits for Y, Dy, and Tb.
• The overall performance of the blanks was deemed to be acceptable to the
CP. There was a small increase in Yttrium values observed and no increase in
values such as terbium and dysprosium.
• Field diamond duplicate data points taken from the same drillholes is
available only for 14 samples from diamond drill core. The mean grade of the
original sample was generally reproduced by the duplicate for the various
analytes and is acceptable to the Competent Person.
• In April 2024, 37 samples were submitted to an umpire laboratory, Intertek
Genalysis in Perth. The results were compared to the original assay results
from ALS laboratories for the key analytes of interest to the project. There
was no observable bias between the original assays completed by ALS and the
checks completed by Intertek Genalysis Perth.
• There are 14 duplicates collected over the entire project drilling campaign.
• Assays for the 63 drillholes were completed at ALS.
Verification
of sampling
and assaying
• The verification of
significant
intersections by
either independent
or alternative
company personnel.
• Victory’s representative Prof Kenneth Collerson (PhD, FAusIMM) undertook
verification of significant intersections.
• The use of twinned
holes.
• Eleven percussion (air core and RC) drillholes have been twinned with
diamond drilling (DD001 to DD011). Samples were submitted to the
laboratory for analysis only where the initial screening by handheld pXRF
satisfied the anomalous value threshold as set by company policy, whereas
the diamond drilling was sampled and assayed along the entire length of the
drillhole.
• QQ plots were prepared between the percussion and diamond assays paired
at 5m, with good correlation between the two drillhole types.
• Documentation of
primary data, data
entry procedures,
data verification,
data storage
(physical and
electronic)
protocols.
• ALS laboratories routinely re-assayed anomalous assays as part of their
normal QAQC procedures
• Discuss any
adjustment to assay
data.
• REO assay results were adjusted to convert elemental values to the oxide
equivalent for REOs. The oxide stoichiometric conversion factors used are
provided below:
Criteria
JORC Code
explanation
Commentary
Location of
data points
• Accuracy and quality
of surveys used to
locate drillholes
(collar and
downhole surveys),
trenches, mine
workings and other
locations used in
Mineral Resource
estimation.
• 51% of the drillholes were surveyed by RTK/DGPS. The remaining holes were
surveyed by handheld GPS with a horizontal accuracy of +/- 5 m. Elevation
values (Z) were assigned from the topography surface where no DGPS data
was available.
• There were no downhole surveys completed. Drillholes were both vertical
and inclined. The majority of drill intervals (99%) were to a drill hole depth of
less than 100m. Downhole survey was completed for the diamond drillholes.
• Specification of the
grid system used.
• All coordinates are in GDA94 Zone 50.
• Quality and
adequacy of
topographic control.
• A LiDAR based DEM has been produced for the project.
Data spacing
and
distribution
• Data spacing for
reporting of
Exploration Results.
• The drillhole spacing at North Stanmore ranges from 50 x 50m to 250 x 100m.
• Whether the data
spacing, and
distribution is
sufficient to establish
the degree of
geological and
grade continuity
appropriate for the
Mineral Resource
and Ore Reserve
estimation
procedure(s) and
classifications
applied.
• Given the nature of the exploration programs, the spacing of the exploration
drilling is appropriate for understanding the exploration potential and the
identification of structural controls on the mineralisation. In areas of closer
spaced drilling the spacing demonstrates grade and geological continuity
sufficient to support Indicated Mineral Resources. Where drillhole spacing
increases, grade and geological continuity can be implied and has been
classified as an Inferred Mineral Resource. Areas where the drillhole spacing
is such that grade and geological continuity cannot be implied, were excluded
from the Mineral Resource.
• The applied Mineral Resource classification is commensurate with the grade
continuity demonstrated.
• Whether sample
compositing has
been applied.
• Percussion samples were collected as 1.0 m samples. Core was collected at a
nominal 1.0 m samples. Air core samples were collected as 1.0 m and 4.0 m
samples.
Orientation
of data in
relation to
geological
structure
• Whether the
orientation of
sampling achieves
unbiased sampling
of possible
structures and the
extent to which this
• Mineralisation is sub horizontal, as such the vertical drillholes are suitable to
test mineralisation thickness.
• It is concluded from aerial magnetics that the mineralisation trends 010°-
030°.
• Air core drilling was vertical as the mineralisation is interpreted to be sub
parallel to the regolith profile. RC percussion drilling was angled.
Criteria
JORC Code
explanation
Commentary
is known,
considering the
deposit type.
• Downhole widths of mineralisation are known with percussion drilling
methods to +/- 1 metre.
• If the relationship
between the drilling
orientation and the
orientation of key
mineralised
structures is
considered to have
introduced a
sampling bias, this
should be assessed
and reported if
material.
• Mineralisation is sub-horizontal. Azimuths and dips of drilling was designed to
intersect the strike of the rocks at right angles.
Sample
security
• The measures taken
to ensure sample
s
Share your feedback